CEMTEC® in Cement Plants andLime Works (Examples)
|
|
|
|
|
Australia |
HOLCIM in Gladstone |
Germany |
LAFARGE in Karsdorf |
Iran |
ZABOL Cement in Zabol |
Mexico |
CYCNA in Arroyo Hondo |
Romania |
Mittal-Steel in Galati |
V.A.E. |
Al Bana Cement |
|
|
|
|
|
|
Project: |
HOLCIM Ltd. Cement Plant in Gladstone, Australia |
| The first CEMTEC® High Temperature Analyser system was delivered in August 2004 to the HOLCIM cement plant in Gladstone, Australia and is measuring in the kiln inlet of a lime rotary kiln. | |
| Technical Data: | |
|
Kiln capacity: |
2500 t/day |
| Probe immersion depth: | 3000 mm |
| Analysis: | InSitu, O2 / COe |
| Delivery / Installation: | August 2004 / by customer |
| After extensive testing ENOTEC GmbH was accepted on the 1st of January 2007 into the HOLCIM supplier list for flue gas analyser systems in cement plants. | |
|
|
|
Project: |
LAFARGE Cement plant in Karsdorf, Germany |
| In January and September 2005 two CEMTEC® High Temperature Analyser Systems were delivered to the LAFARGE cement plant in Karsdorf and installed into the inlets of two rotating kilns. | |
| Technical data: | |
|
Kiln capacity: |
each 2500 t/day each |
| Probe immersion depth: | 3000 mm |
| Analysis: | InSitu, O2 / COe |
| Delivery / Installation: | January 2005 / January 2005 and September 2005 / September 2005 |
| In December 2006 a further CEMTEC® Analyser System was delivered and installed into a second LAFARGE cement plant in Germany. | |
|
|
|
Project: |
ZABOL Cement in Zabol, Iran |
| In May 2008 a CEMTEC® High Temperature Analyser System for the measurement of oxygen was delivered to the cement plant in Zabol in Iran | |
| Technical Data: | |
Kiln capacity: |
3000 t/day |
| Probe immersion depth: | 3500 mm |
| Analysis: | InSitu, O2 |
| Delivery / Installation: | May 2008 / by customer |
|
|
|
Project: |
CYCNA in Arroyo Hondo, Mexico |
| In July 2008 a CEMTEC® High Temperature Analyser System for the measurement of O2 was delivered to the CYCNA Cement plant in Arroyo Hondo in Mexico. The system was installed and started up in August 2008. | |
| Technical Data: | |
| Kiln capacity: |
3000 t/day |
| Probe immersion depth: | 3000 mm |
| Analysis: | InSitu, O2 |
| Delivery / Installation: | July 2008 / August 2008 |
|
|
|
Project: |
Mittal-Steel in Galati, Romania |
| In 2007 a total of 5 CEMTEC®
High Temperature Analyser Systems were delivered to the steelworks of
Mittal-Steel in Galati, Romania and installed into the corresponding
rotating lime kilns. The CEMTEC®
Analyser Systems were installed and started up by ENOTEC from
September through January 2008.
At this project the CEMTEC® High Temperature Probes act as sampling probes for the extractive measurement of O2. |
|
| Technical Data: | |
Kiln capacity: |
each 1750 t/day each |
| Probe immersion depth: | 2000 mm |
| Analysis: | Probes operate as sampling probes; the O2 measurement is extractive |
| Delivery / Installation: | July to November 2007 / September 2007 to January 2008 |
|
|
|
Project: |
Al Bana Cement in the United Arab Emirates |
|
In February 2009 a CEMTEC®
High Temperature Analyser System was delivered to the cement
plant of Al Bana Cement in the U.A.E. This system measures 'InSitu'
the
oxygen concentration in the rotating kiln inlet. In addition, CO and NO are
measured extractively from the measuring gas which is extracted by the
CEMTEC® probe. In addition, two multi-purpose probes for the measurement of volumetric flow, dust, temperature and pressure and a second analyser cabinet with a further sampling probe for the measurement of the CO and NO content at the preheater have been included in the ENOTEC scope of delivery. |
|
| Technical Data: | |
Kiln capacity: |
2500 t/day |
| Probe immersion depth: | 3000 mm |
| Analysis: | InSitu O2 and extractive CO / NO |
| Delivery / Installation: | February 2009 / by customer |
|
|
|